1. Particular and Use
This product is suitable for connection line of electrical instrument and transmission line of automatic control system in AC rated voltage 450 / 750V and below. There are many excellent performances, for example oil resistant, waterproof, wear-resistant, acid and alkali resistance and corrosive gas resistant, ageing resistance, fire resistance, etc. It’s fit for the metallurgy, power, petrochemical and other industries.
2. Product Standard:
Q/HHTZH004.1, The flame retardant control cable also should comply with the GB12666-90 standard.
3. Property for Use:2) The highest work temperature:
F46 insulated is not more than 200 Degree Celsius.
PFA insulated is not more than 260 Degree Celsius.
3) The lowest environment temperature:
a. PVC sheath: It is -40 Degree Celsius in fixed laying. It is -15 Degree Celsius in non fixed laying.
b. F46, PFA and Silicone rubber sheath: It is -60 Degree Celsius in fixed laying. It is -20 Degree Celsius in non fixed laying.
4) For laying cable, the temperature should be not lower than 0 Degree Celsius. (It is not lower than -25 Degree Celsius with F46, PFA, Silicone rubber and Butyl Nitrile sheath cable.)
5) Permissible bending radius of cable is as follows:
a) For non armored cables, should be not less than 6 times of cable overall diameter;
1) AC Rated voltage (U0/U): 450/750V.
b) For the cable with armored or copper tape shielded cable, should be not less than 12 times of cable overall diameter;
c) F46, PFA insulated and sheath cable, should be not less than 8 times of cable overall diameter.
4. Code and interpretation
item | code | interpretation |
Fire resistance | ZR | Grade A,B,C |
Type | K | Control cable |
Insulation material | F | Fluorinated Ethylene Propylene (F46) |
(ZR192-)F | Soluble Polytetrafluoroethylene (PFA) | |
Sheath material | F | Fluorinated Ethylene Propylene (F46) |
(ZR192-)F | Soluble Polytetrafluoroethylene (PFA) | |
V | Polyvinyl Chloride (PVC) | |
G | Silicone rubber | |
Shielded material | P | Copper wire weaving shielding |
P1 | Tinned copper wire shield | |
P2 | Copper tape wrapped shielding | |
P3 | Aluminum- plastic wrapped shielding | |
Armored material | 22 | Steel tape armored PVC sheathed |
23 | Steel tape armored PE sheathed | |
32 | Steel wire armored PVC sheathed | |
33 | Steel wire armored PE sheathed | |
Conductor structure | A | Single strand |
B | stranded inner conductor of 7 strands | |
R | Stranded inner conductor of many strands |
Shielded Control Cable